Central panel of the fireplace.
Outlet joint.
Screws and supporting steel of central plate.
Central cleaning outlet.
The Paris model has 5 cleaning hatches, which are accessible on the front of the stove (3 hatches), by
removing the grate, as in Drawing 19. To remove the grate, first lubricate the screws that secure it. The 2
remaining hatches are in the convection chamber, which is accessed by opening the corresponding side door
and removing the convection chamber plate as shown in Drawing 20.
Burn pot.
Cleaning outlet.
Convection chamber plate.
Cleaning outlet.
Side door.
It is recommendable to calculate the frequency with which you clean the outlet cleaning considering the
hours of operation, thus avoiding ash saturation.
Once you clean the walls of the stove, you must be sure that the cleaning outlet is securely closed, since the
proper operation of the stove depends on this cleaning.
5.9.
Cleaning of the exhaust circuit of the stove, extractor's collector.
For an optimal cleaning of the extractor's collector, it is recommended to dismantle the extractor itself in
order to have full access to this zone for a better cleaning. Once the extractor is dismantled, clean it with a
dry brush and be careful with the turbine and structure.