BFT THALIA P Instrucciones De Instalación página 34

Ocultar thumbs Ver también para THALIA P:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Logic
Definition
1 motor active
1 MOT. O N
Inversion of the mo-
change mot
tor's phase shift
OPEN IN OTHER
Open in other
direction
DIRECT.
Configuration of
safety input SAFE 1.
SAFE 1
Configuration of
safety input SAFE 2.
SAFE 2
Configuration of
safety input SAFE 3.
SAFE 3
Configuration of
safety input SAFE 4.
SAFE 4
Configuration of
safety input SAFE 4.
SAFE 5
Configuration of
safety input SAFE 6.
SAFE 6
Configuration of
command input IC 1.
IC 1
Configuration of
command input IC 2.
IC 2
Configuration of
command input IC 3.
IC 3
Configuration of
command input IC 4.
IC 4
Configuration of
AUX 0
AUX 0 output. 20-21
Configuration of
AUX 1 output.
AUX 1
Configuration of
AUX 2 output.
AUX 2
Configuration of
AUX 3 output.
AUX 3
Type of lock.
LOCK
Fixed code
FIXED CODE
34 -
THALIA P
INSTALLATION MANUAL
Cross out
Default
setting
used
0
0
1
0
0
1
0
0
1
0
0
1
72
2
3
6
74
4
5
2
77
6
7
4
79
8
9
0
79
10
11
12
6
84
13
14
0
0
1
61
2
4
3
62
4
2
5
64
3
6
65
0
6
1
2
3
3
4
22-23
5
6
1
7
24-25
8
9
0
10
26-37
0
1
0
28-29
2
3
0
0
1
Both motors active (2 leaves).
Only motor 1 active (1 leaf ).
Open: M1 starts in advance compared to M2 (opening phase shift). (See Fig.E)
Closure: M2 starts in advance compared to M1 (closing phase shift). (See Fig.E)
Pedestrian manoeuvre is performed by M1
Open: M2 starts in advance compared to M1 (opening phase shift). (See Fig.E)
Closure: M1 starts in advance compared to M2 (closing phase shift). (See Fig.E)
Pedestrian manoeuvre is performed by M2
Standard operating mode (See Fig.E).
Opens in other direction to standard operating mode (See Fig. E)
Input configured as Phot (photocell).
Input configured as Phot test (tested photocell).
Input configured as Phot op (photocell active during opening only).
Input configured as Phot op test (tested photocell active during opening only).
Input configured as Phot cl (photocell active during closing only).
Input configured as Phot cl test (tested photocell active during closing only).
Input configured as Bar, safety edge.
Input configured as Bar, tested safety edge.
Input configured as Bar 8k2 (Inactive on SAFE 3,4,5,6).
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the
movement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while
closing, the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
movement stops.
(Inactive on SAFE 3,4,5,6).
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the
movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
movement stops.
(Inactive on SAFE 3,4,5,6).
Input configured as Start E.
Input configured as Start I.
Input configured as Open.
Input configured as Close.
Input configured as Ped.
Input configured as Timer.
Input configured as Timer Pedestrian.
Output configured as 2nd Radio Channel.
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light
Output configured as Alarm
Output configured as Flashing light
Output configured as Latch
Output configured as Magnetic lock
Output configured as Maintenance
Output configured as Flashing Light and Maintenance.
Output configured as 12V
solenoid latch.
Output configured as 12V
magnetic lock.
Output configured as 24V
solenoid latch.
Output configured as 24V
magnetic lock.
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
Optional extras
Tabla de contenido
loading

Tabla de contenido