HydroPower® Ultra
Resin change & Technical data
• Inspect system head assembly: O-ring is in good condition.
Re-coat o-ring with silicone lubricant only.
• Re-install DI System head assembly, press it slightly, then turn it 1/8
clockwise while fixing the base unit with your feet.
• System is ready to be operated.
The green ring on upper Ultra Resin Pack seals the system, ensuring optimum
resin performance.
Never use other resin in this system! This leads to have water spillage in the
top cap and a low resin performance!
4. RECONNECT WATERFED POLE TUBING (fig. H)
• Turn "ON" water supply at tap (fig. I).
• Inspect system as it pressurizes.
• Keep discharge line open and hold down yellow lever to remove
trapped air from system (fig. J).
5. TEST SYSTEM TDS (fig. K) The value should be at 000.
6.3 Dynamic Flow Control
The ideal water flow in this system is 120l/hour. To make the performance of
HydroPower
Ultra independend from incoming water suppply pressure,
®
a dynamic flow control is included to the Water In Valve. (fig. L)
It reduces the water flow to 2l/minute (= 120l/hour).
You can easily remove the Dynamic Flow Control (fig. M) to achieve a higher
water flow than 120l/h.

7. Technical Data

Factor
Weight incl resin
Height
Inner Diameter
Dimension of base
Ultra Resin Packs
Max. permanent pressure (bar)
Max. water temp. (°C)
Min. water temp. (°C)
DIUH1
10 kg
35 cm
20 cm
28 x 30cm
1x
max. 8
30
5
www.ungerglobal.com
DIUH2
DIUH3
22 kg
31 kg
76,5 cm
107 cm
20 cm
20 cm
28 x 30cm
28 x 30cm
1x
, 2x
1x
max. 8
max. 8
30
5
H
I
J
K
L
M
, 2x
30
5
11