Safety and operating instructions
Overview
To reduce the risk of serious injury or death
to yourself or others, read the Safety
instructions section found on the previous
pages of this manual before operating the
machine.
Design and function
These instructions are valid for the CP 1210, CP 1230
and CP 1240. The CP 1210, CP 1230 and CP 1240
are designed for medium to heavy demolition of
materials such as concrete and asphalt. The
pneumatic breakers are designed for vertical use.
No other use is permitted. To choose the correct
insertion tool, see the spare parts list.
Choosing the correct
breaker for a task
It is important to choose the correct size of breaker
for the work to be performed.
A breaker that is too small means that the work will
take longer.
A breaker that is too large means that there must be
frequent repositioning, which is unnecessarily tiring
for the operator.
A simple rule for choosing the correct size of breaker
is that a normal sized piece of broken material should
be removed from the workpiece within 10–20
seconds operation.
>
If it takes less than 10 seconds a smaller breaker
should be selected.
>
If it takes more than 20 seconds a larger breaker
should be selected.
12
www.CrowderSupply.com • Toll Free: 888-883-5144
CP 1210, CP 1230, CP 1240
Main parts
CP 1210
CP 1230 and 1240
A.
Trigger (start/stop device)
B.
Handle
Back head
C.
Air intake
D.
Muffler
E.
F.
Front head
G.
Latch
9800 0608 90d | Original instructions