ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC
DRYERS
For electrical connections using a
power cord:
WARNING
Use a new UL-listed 240V 30 amp dryer power supply cord
with closed ring terminals or spade terminals with upturned
ends.
Use a UL-listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical shock.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer
must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electric
shock by providing a path of least resistance for electric
current. This dryer uses a cord having an equipment-
grounding conductor and a grounding plug. The plug
must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all
local codes and ordinances.
Improper connection of the
WARNING
equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified
electrician, or service representative or personnel, if
you are in doubt as to whether the appliance is properly
grounded. DO NOT modify the plug on the power supply
cord. If it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
WARNING
- Electrical Shock Hazard
TO PREVENT ELECTRIC SHOCK, DISCONNECT POWER
BEFORE SERVICING.
This dryer should be connected to an individual branch
circuit with 10 gauge copper wire minimum through a 30
amp fuse or circuit breaker. DO NOT fuse neutral.
Use copper conductors only.
16
INSTALLATION INSTRUCTIONS
- Fire Hazard
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC
DRYERS
For direct wire connections:
WARNING
- Fire Hazard
Use 10 gauge copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical shock.
GROUNDING INSTRUCTIONS
For a permanently connected dryer: This dryer must
be connected to a grounded metal, permanent wiring
system, or an equipment-grounding conductor must
be run with the circuit conductors and connected to
the equipment-grounding terminal on the appliance.
Improper connection of the equipment-grounding
conductor can result in a risk of
WARNING
electric shock. Check with a qualified
electrician, or service representative or personnel, if
you are in doubt as to whether the appliance is properly
grounded.
SAVE THESE INSTRUCTIONS
WARNING
- Electrical Shock Hazard
TO PREVENT ELECTRIC SHOCK, DISCONNECT POWER
BEFORE SERVICING.
This dryer should be connected to an individual branch
circuit with 10 gauge copper wire minimum through a 30
amp fuse or circuit breaker. DO NOT fuse neutral.
Use copper conductors only.
49-3000195