Operation Control; Introduction To Users; Electrical Connection; Earthing - Diamond G77/4BFE7-N Manual Del Usuario

Idiomas disponibles
  • ES

Idiomas disponibles

2.6.4

OPERATION CONTROL

- Start the unit in accordance with the use instructions.
- Make sure there are no leaks following the local procedures.
- Check the ignition and interignition of the pilot burner and the main burner.
- Make sure the flue gases are discharged regularly.
- Write on a sticker, to be glued to the unit label, for what gas and pressure the unit has been calibrated
2.7

INTRODUCTION TO USERS

Explain the operation and use to the user by consulting the manual, and illustrate any changes.
Leave the manual in the user's hands and explain the he/she should use it for further reference.
3.
FOR UNITS WITH ELECTRIC OVEN ONLY
Electrical connection should be performed in compliance with the CEI regulations, only by authorised and competent
personnel. In the first instance, examine the data shown on the technical data table of this manual, on the label and on the
electrical diagram. The envisaged connection is of the fixed type. The position of the terminal box, accessible by removing
the left side, is explained, for each model, on the present manual and on the oven base itself.
IMPORTANT: Ahead of each unit it is necessary to install an omnipolar main breaker, having a spacing among contacts of
at least 3mm; example:
- manual breaker of appropriate capacity, complete with fuse valves
- automatic breaker with respective magnetothermal relays.
3.1

EARTHING

It is essential to earth the unit.
To this purpose, it is necessary to connect to an efficient earthing system the terminals marked with the symbols (
on the line-receiving terminal box. The earthing system should comply with the law in force.
SPECIFIC WARNINGS
The electrical safety of this unit is assured only when it is correctly connected to an efficient earthing system as stated
in the electrical safety regulations in force; the Manufacturer declines any responsibility for the non-compliance with
these safety regulations.
It is necessary to verify this fundamental safety requisite and, in case of doubt, ask for an accurate testing of the system by
professionally qualified personnel.
The Manufacturer cannot be deemed responsible for any damages caused by the lack of unit earthing.
ATTENTION: NEVER INTERRUPT THE EARTH WIRE (Yellow-Green)
3.2

POWER SUPPLY CABLE

The unit is supplied fitted for the following voltages: 3N AC 380...415V; 3 AC 220...240V; 1N AC 220...240V 50Hz.
The flexible cable for power supply connection should not have characteristics lower than the rubber insulation type H07RN-F.
The cable should be inserted through the cable clasp and firmly fastened. Furthermore, the supply voltage with the unit
functioning should not go outside the value of the nominal tension ±10%.
3.3

EQUIPOTENTIAL

The unit should be included within an equipotential system whose efficiency must be tested according to the law in force.
The screw marked with the label "Equipotential" is located near the terminal box on the base.
3.4

ELECTRICAL CABLE CONNECTION

Gas units with electrical oven are supplied fitted to function at a voltage of 1N AC 220...240V 50 Hz; to carry out the electrical
connection it is necessary to:
- disassemble the left side
- connect the supply cable to the terminal box in accordance with the main supply voltage, following the electrical diagram.
The adhesive label is located near the terminal box.

ELECTRICAL CONNECTION

- 19 -
) placed
GB
loading

Este manual también es adecuado para:

B-g4sfe77