Tabella Di Programmazione Dei Dip Switch Per Funzioni Speciali; Dip Switch Special Function Programming Table; Tableau De Programmation Des Dip Switches Pour Fonctions Spéciales; Programmeringstabel Van De Dipswitches Voor Speciale Functies - Comelit Ikall Manual Tecnico

Ocultar thumbs Ver también para Ikall:
Tabla de contenido
Codice /
Dip switch ON
Code
223
1,2,3,4,5,7,8
Comando serratura su SE in AC (default)
224
6,7,8
Comando serratura su SE in AC potenziata
225
1,6,7,8
Comando serratura su SE in DC
245
1,3,5,6,7,8
Tempo serratura: 2 sec + tono disattivo (default)
246
2,3,5,6,7,8
Tempo serratura: 4 sec
247
1,2,3,5,6,7,8
Tempo serratura: 8 sec
248
4,5,6,7,8
Tono conferma serratura: attivo
251
1,2,4,5,6,7,8
Relè C.NC.NO in parallelo a SE (default)
252
3,4,5,6,7,8
Apriporta sempre attivo (default)
253
1,3,4,5,6,7,8
Apriporta attivo solo per utente chiamato
Gestione comando attuatore
N.B. sull'impianto non deve essere presente
l'Art. 1256 in modalità attuatore generico.
Attivazione
229
1,3,6,7,8
attuatore: 2 sec
Attivazione
230
2,3,6,7,8
attuatore: 4 sec
Attivazione
231
1,2,3,6,7,8
attuatore: 8 sec
Comando attuatore su linea seriale S: disattivo
228
3,6,7,8
(default)
227
1,2,6,7,8
Comando attuatore su linea seriale S: attivo
232
4,6,7,8
Tempo di attesa risposta: 60 sec (default)
233
1,4,6,7,8
Tempo di attesa risposta: 120 sec
234
2,4,6,7,8
Tempo di attesa risposta: 30 sec
235
1,2,4,6,7,8
Tempo di conversazione: 90 sec (default)
236
3,4,6,7,8
Tempo di conversazione: 180 sec
237
1,3,4,6,7,8
Autoaccensione: attiva (default)
238
2,3,4,6,7,8
Autoaccensione: disattiva
Tono conferma su chiamata utente: attivo
239
1,2,3,4,6,7,8
(default)
240
5,6,7,8
Tono conferma su chiamata utente: disattivo
243
1,2,5,6,7,8
Tempo di attesa reset: 10 sec (default)
244
3,5,6,7,8
Tempo di attesa reset: 1 sec
208
5,7,8
Reset dopo apriporta in fonica: attivo (default)
209
1,5,7,8
Reset dopo apriporta in fonica: disattivo
249
1,4,5,6,7,8
Invio chiamata: singola (default)
250
2,4,5,6,7,8
Invio chiamata: tripla
Gestione posti interni collegati all'Art. 1622: fi no
241
1,5,6,7,8
a 70 (default)
Gestione posti interni collegati all'Art. 1622: da
242
2,5,6,7,8
71 a 100
000
Simplebus (default)
255
1,2,3,4,5,6,7,8
Simplebus Top
254
2,3,4,5,6,7,8
IT
Serratura
Door lock command on SE in AC (default)
Door lock command on SE in enhanced AC
Door lock command on SE in DC
Door lock time: 2 sec + deactivation tone
(default)
Door lock time: 4 sec
Door lock time: 8 sec
Door lock confi rmation tone: enabled
C.NC.NO relay in parallel with SE (default)
Lock-release always enabled (default)
Lock-release only enabled for user called
N.B. the system should not include Art. 1256
in generic actuator mode.
relè
C.NC.NO
su
comando
Enabling C.NC.NO relay on actuator control: 2
sec
relè
C.NC.NO
su
comando
Enabling C.NC.NO relay on actuator control: 4
sec
relè
C.NC.NO
su
comando
Enabling C.NC.NO relay on actuator control: 8
sec
Actuator control on serial line S: disabled
(default)
Actuator control on serial line S: enabled
Funzioni impianto
Awaiting response time: 60 sec (default)
Awaiting response time: 120 sec
Awaiting response time: 30 sec
Talk time: 90 sec (default)
Talk time: 180 sec
Self-ignition: enabled (default)
Self-ignition: disabled
Confi rmation tone on user call: enabled (default)
Confi rmation tone on user call: disabled
Reset wait time: 10 sec (default)
Reset wait time: 1 sec
Reset after lock-release in audio: enabled (default) Reset après ouverture gâche en phonie : actif
Reset after lock-release in audio: disabled
Call transmission: single (default)
Call transmission: triple
Control of internal units connected to Art. 1622:
up to 70 (default)
Control of internal units connected to Art. 1622:
from 71 to 100
Modalità impianto
Simplebus (default)
Simplebus Top
Ripristino default
EN
Door lock
Actuator control management
System functions
System mode
Restore default
FR
Gâche
Commande gâche sur SE en CA (par défaut)
Commande gâche sur SE en CA intensifi é
Commande gâche sur SE en CC
Temps gâche : 2 sec + tonalité désactivée (par
défaut)
Temps gâche : 4 sec
Temps gâche : 8 sec
Tonalité confi rmation gâche : active
Relais C.NC.NO en parallèle à SE (par défaut)
Ouvre-porte toujours actif (par défaut)
Ouvre-porte actif uniquement pour usager
appelé
Gestion commande actionneur
N.B. l'Art. 1256 en modalité actionneur
générique ne doit pas être présent dans
l'installation.
Activation relais C.NC.NO sur commande
actionneur : 2 sec
Activation relais C.NC.NO sur commande
actionneur : 4 sec
Activation relais C.NC.NO sur commande
actionneur : 8 sec
Commande actionneur sur ligne série S :
désactivée (par défaut)
Commande actionneur sur ligne série S : active
Fonctions installation
Temps d'attente réponse : 60 sec (par défaut)
Temps d'attente réponse : 120 sec
Temps d'attente réponse : 30 sec
Temps de conversation : 90 sec (par défaut)
Temps de conversation : 180 sec
Auto-allumage : actif (par défaut)
Auto-allumage : désactivé
Tonalité confi rmation sur appel usager : activée
(par défaut)
Tonalité confi rmation sur appel usager :
désactivée
Temps d'attente reset : 10 sec (par défaut)
Temps d'attente reset : 1 sec
(default)
Reset après ouverture gâche en phonie : non actif
Envoi appel : simple (par défaut)
Envoi appel : triple
Gestion postes intérieurs reliés à l'Art. 1622 :
jusqu'à 70 (par défaut)
Gestion postes intérieurs reliés à l'Art. 1622 :
de 71 à 100
Modalité installation
Simplebus (par défaut)
Simplebus Top
Rétablissement réglage d'usine
11
Tabla de contenido
loading

Este manual también es adecuado para:

1622Ikall 1622

Tabla de contenido