8.
MAINTENANCE/STORAGE INSTRUCTIONS
8.1 After use and before performing maintenance, unplug and disconnect the battery charger.
8.2 Use a dry cloth to wipe all battery corrosion and other dirt or oil from the connector, cords
and the charger case.
8.3 Servicing does not require opening the unit, as there are no user-serviceable parts.
Servicing should be performed only by qualified service personnel.
8.4 Store the charger unplugged, inside, in a cool, dry place.
9.
TROUBLESHOOTING
PROBLEM
Power light will not turn on.
CHARGING
flashing.
CHARGING
not lit.
10. BEFORE RETURNING FOR REPAIRS
10.1 When a charging problem arises, make certain that the battery is capable of accepting a
normal charge. Double check all connections, the AC outlet for a full 120V and the quality
of the connections from the connector to the battery system. The connector must be clean.
10.2 When an UNKNOWN OPERATING PROBLEM arises, please read the complete manual and
call the customer service number for information. This will usually eliminate the need for return.
7:00 a.m. to 5:00 p.m. Central Time, Monday through Friday
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.
11. SPECIFICATIONS
Input Voltage ........................................................................................................... 120 VAC
Output Current Rating ........................................................................... 12V/16V/24V – 1.5A
Maximum Charge Voltage ............................................................................................ 30.8V
Maintain Voltage ........................................................................................................... 27.2V
Size ........................................................................................................2⅝" H x 6" W x 3" D
Weight ......................................................................................................................... 2½ lbs
12. REPLACEMENT PARTS
XLR Connector Komex Assembly ................................................................... 3899002743Z
POSSIBLE CAUSE
AC outlet is dead.
Poor electrical connection.
Charger is in abort mode.
LED is
Battery is too large.
Battery is not connected.
LED is
Battery is deeply sulfated.
If the above solutions do not eliminate the problem,
or for more information about troubleshooting,
call toll-free from anywhere in the U.S.A.
1-800-621-5485
5
•
•
REASON/SOLUTION
Check for an open fuse or
circuit breaker supplying the
AC outlet.
Check the power cord and
extension cord for a loose
fitting plug.
Check cable or have battery
checked.
Unplug charger from AC and
plug back in, to reset.
Connect charger to battery.
Have battery checked.