7.
By screwing or unscrewing the two screws (A) on the motor,
the two limit switches can be adjusted; then, using the two
screws (B) block the two adjusting screws
A
Opening
B
8.
Replace the cover and tighten the two screws
9.
Finally, secure the gear motor by turning the release key
10. For the assembly of the second motor, carry out the same
operations proceeding in reverse order for the adjustment of
the limit switches
11. After installing and adjusting the motors, position the
leaves halfway along their stroke so that, after making the
electrical connections, they can learn the opening and closing
procedures correctly
Closing
A
B
3.6 - ELECTRICAL CONNECTIONS
m
WARNING!
•
An incorrect connection can cause faults or dangerous
situations; therefore, scrupulously comply with the
indicated connections.
•
Perform the connection operations with the power
supply disconnected.
1.
Remove the gear motor cover
B
2.
Loosen the cable gland of the gear motor and insert the
connection cables
B
3.
Bring the cables to the top of the motor near the control unit
4.
To connect the two motors, refer to the part of the manual
relating to the "Control unit"
- 43 -
C
A
A