Lock; External Aerial; Plug In Receiver; Adi Interface - V2 ZORUS Manual Del Instalador

Actuador electromecánico irreversible de brazo articulado para cancelas batientes
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4.11 - LOCK

An electric lock can be assembled on the gate, to ensure a good
closing of doors. Make use of a 12V lock.
Connect lock cables to terminals K4 and K5 of the control unit.

4.12 - EXTERNAL AERIAL

We suggest to use the external aerial (model: ANS433) in order to
guarantee the maximal range.
RECEIVER
Connect the antenna hot pole to terminal A2 (ANT) of the
control unit and the braiding to terminal A1 (ANT-).
NOTE: using the LUMOS flashing light with built-in antenna,
connect the terminal 3 of the flashing light to the terminal
A2 (ANT) of the control unit and the terminal 4 of the flashing
light to the terminal A1 (ANT-) of the control unit PD12
+
TERY

4.13 - PLUG IN RECEIVER

PD12 control unit is suitable for plugging in a MR2 receiver having
a high-sensitivity super-heterodyne architecture.
m
WARNING: it is necessary to turn off the control unit
power before doing the operations mentioned here below.
Pay attention to the way you connect the removable
modules.
MR2 module receiver is provided with 4 channels and each of
them is suitable for a command of PD12 control unit:
g
• CHANNEL 1
START
g
• CHANNEL 2
PEDESTRIAN START
g
• CHANNEL 3
STOP
g
• CHANNEL 4
COURTESY LIGHT
NOTE: Before programming 4 channels and function
logics read carefully the instructions of MR2.

4.14 - ADI INTERFACE

The ADI (Additional Devices Interface) interface of the control unit
PD12 allows the connection to V2 optional modules.
Refer to V2 catalogue or to the technical sheets to see which
optional modules with ADI interface are available for this control
unit.
NOTE Please read the instructions of each single module to
install the optional modules.
Max 500mA
M2
24Vdc
M1
Control unit model: PD12
24Vdc
24 Vdc

POWER SUPPLY

Max 500mA
RECEIVER
Control unit model: PD12
4.15 - POWER SUPPLY
The control unit must be fed by a 230V 50Hz electric line,
protected by a differential magnetothermal switch complying with
the law provisions in force.
Connect the power supply wires to terminals L and N on the
board located next to the transformer.
Connect the earth cable to terminal

4.16 - BATTERY POWER

In the case of an electricity black-out, the device may be powered
using a battery pack (accessory code 161212).
The battery pack should be housed in the specific seating, as
shown in the figure.
Connect the battery pack connecter to the BATTERY terminals on
the control unit.
M2
24Vdc
+
BATTERY
M1
24Vdc
24 Vdc
POWER SUPPLY
- 47 -
Fuse: 5A
Max 5
RECEIVER
Tabla de contenido
loading

Tabla de contenido