86
drainage
• Install the drain hose so as to be downward slope without fail.
• Do not install the drainage as shown below.
• Pour water in the drain pan of the indoor unit and confirm that
drainage is carried out securely outdoors.
• In case that the attached drain hose is in a room, please apply heat
insulation to it without fail.
refrigerant charge label
This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type: R410A
GWP* value: 2088
GWP = global warming potential
Please fill in with indelible ink
1: The factory refrigerant charge.
2: The additional refrigerant amount charged in the field and
1+2: the total refrigerant charge
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop valve cover).
A. Contains fluorinated greenhouse gases covered by the Kyoto Pro-
tocol.
B. Factory refrigerant charge of the product: see unit name plate