3. Safety
Safety-related maximum values (ATEX and IECEx)
Intrinsically safe supply and signal circuit (current loop 4 ... 20 mA)
Equipment protection level
EN
Voltage Ui
Current Ii
Power Pi
Effective internal capacitance Ci
Effective internal inductance Li
1) For value see product label
2) Equipment Protection Level (EPL): The protection level that is defined for an instrument, where the degree of the probability of an ignition forms the basis.
Ambient temperature range, correlation to the instrument category, temperature class (ATEX and IECEx)
Model
Model IL-10, with PUR cable
10
Ma
2)
DC 30 V
100 mA
1 W
1)
16.5 nF + 0.1 nF/m
1)
0 µH + 1 µH/m
EPL
Ambient and medium
temperature
Ma
-30 ... +80 °C
Ga, Ga/Gb, Gb
-30 ... +60 °C
-30 ... +80 °C
-30 ... +80 °C
Da, Da/Db, Db
-30 ... +40 °C (750 mW)
-30 ... +70 °C (650 mW)
-30 ... +80 °C (550 mW)
WIKA operating instructions submersible pressure transmitter model IL-10
Ga, Ga/Gb, Gb
DC 30 V
100 mA
1 W
16.5 nF + 0.1 nF/m
0 µH + 1 µH/m
Temperature class, surface
temperature
1)
not applicable
T6
T5
T4
120 °C
120 °C
120 °C
Da, Da/Db, Db
DC 30 V
100 mA
750/650/550 mW
16.5 nF + 0.1 nF/m
0 µH + 1 µH/m