3.12 Rear panel

1
Power supply cable
Connects the system to the mains.
2
Gas fitting
3
Signal cable (CAN-BUS) input (RC)
4
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.

3.13 Sockets panel

1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.
3
Gas fitting
4
Signal cable (TIG Torch) input
40

4 ACCESSORIES

4.1 General

Operation of the remote control is activated when connected
to the power sources. This connection can be made also with
the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.

4.2 RC 100 remote control

The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".
4.3 RC 120 pedal remote control unit for TIG
welding
Once the power source has been
switched to the EXTERNAL CONTROL
mode, the output current is controlled
from a minimum to a maximum value
(can be entered from SETUP) by varying
the foot pressure on the pedal surface. A
microswitch provides the start trigger sig-
nal at minimum pressure.

4.4 RC 180 remote control

This remote control unit makes it possible to change the output
current without interrupting the welding process.
"Consult the instruction manual".