Porter Cable C2002 Manual De Instrucciones página 11

Ocultar thumbs Ver también para C2002:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Air Compressor Pump (not shown): Compresses air into the air tank. Working air
is not available until the compressor has raised the air tank pressure above that
required at the air outlet.
Drain Valve: The drain valve is located at the base of the
air tank and is used to drain condensation at the end of
each use.
Check Valve: When the air compressor is operating, the
check valve is "open", allowing compressed air to enter
the air tank. When the air compressor reaches "cut­out"
pressure, the check valve "closes", allowing air
pressure to remain inside the air tank.
Motor Overload Protector (not shown): The
motor has an automatic reset thermal overload
protector. If the motor overheats for any reason,
the overload protector will shut off the motor.
The motor must be allowed to cool down before
restarting.
The compressor will automatically
restart after the motor cools.
HOW TO USE YOUR UNIT
How to Stop
Set the On/Off switch to "Off".
Before Starting
Do not operate this unit until you read this instruction manual
for safety, operation and maintenance instructions.
Before Each Start-Up
1.
Set the On/Off switch to "Off".
Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage
2.
and Circuit Protection paragraph in the Installation section of this manual.)
3.
Turn the regulator knob counterclockwise to set the outlet pressure to zero.
4.
Attach hose and accessories.
Risk of unsafe operation. Firmly grasp air hose in hand when
installing or disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn acces-
sories.
NOTE: The hose or accessory will require a quick connect plug if the air outlet is
equipped with a quick connect socket.
Risk of Bursting. Too much air pressure causes a hazardous
risk of bursting. Check the manufacturer's maximum pressure rating for air
tools and accessories. The regulator outlet pressure must never exceed the
maximum pressure rating.
Risk of property damage. Compressed air from the unit may
contain wa ter condensation and oil mist. Do not spray un fil tered air at an item
that could be damaged by moisture. Some air tools and accessories may require
filtered air. Read the in struc tions for the air tools and accessories.
How to Start
1.
Set the On/Off switch to "On" and allow tank pressure to build. Motor will stop
when tank pressure reaches "cut-out" pressure.
Check Valve
11 - ENG
Drain
Valve
Tabla de contenido
loading

Tabla de contenido