USING THE 50 AMP BATTERY CLAMPS
1. Connect the end of the charger output cable to the end of the battery cable,
quick-connect and clamps.
2. Follow the steps in sections 6 and 7 to connect the output clamps to the battery.
3. Connect the charger to an electrical power outlet.
USING THE RING CONNECTORS
1. To permanently attach to a battery, loosen and remove each nut from the bolt
at the battery terminal.
2. Connect the red POSITIVE connector ring to the POSITIVE battery terminal.
3. Connect the black NEGATIVE connector ring to the NEGATIVE battery terminal.
4. Replace and tighten the nuts to secure.
5. Connect the cable to the end of the charger output cord. Take care to keep
the wires and plug away from metal and moving parts.
6. Connect the charger to an electrical power outlet.
BATTERY CHARGING TIMES
CCA = Cold Cranking Amps
SMALL BATTERIES
Motorcycle, garden tractor, etc.
CARS AND TRUCKS
MARINE/DEEP-CYCLE
Times are based on a 50% discharged battery and may change, depending on age and
condition of battery.
AUTOMATIC CHARGING MODE
When an automatic charge is performed, the charger switches to the maintain
mode (see below) automatically after the battery is charged.
ABORTED CHARGE
If charging cannot be completed normally, charging will abort. When charging
aborts, the charger's output is shut off and the CHARGING
LED will flash. To reset after an aborted charge, unplug the charger from the AC
outlet, wait a few moments and plug it back in.
RC = Reserve Capacity
BATTERY SIZE/RATING
200-315 CCA
315-550 CCA
550-1000 CCA
6-12 Ah
12-32 Ah
40-60 RC
60-85 RC
85-190 RC
80 RC
140 RC
160 RC
180 RC
• 10 •
Ah = Amp Hour
CHARGE TIME (1.5A)
2¾-5 h
5-13¼ h
15-19¼ h
19¼-24½ h
24½-46¼ h
23½ h
36 h
40 h
44 h
(yellow/orange)