INSTALLATION
• Mixer: supply with cold water and hot water at 70°C maximum (we recommend 45°C to avoid the risk
of scalding).
• Pressure: 1 - 5 bar (100 - 500kPa), we recommend 3 bar (300kPa).
Maximum pressure differential at the inlets: 1 bar.
• Take care not to pinch the flexibles (Fig. A).
REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.
INSTALLING THE MIXER
- Mount the mixer body on the washbasin or sink (drill hole Ø34-37mm) and tighten the two nuts on
the threaded rods.
- Connect using F3/8" PEX flexibles.
- Ensure a suitable waterproof seal between the mixer and the work plan appropriate to the type
of installation.
ADJUSTING THE FLOW RATE
• Sink mixers: flow rate limited to 9 lpm at 3 bar.
ADJUSTING THE TEMPERATURE
The mixer is supplied without the temperature limiter installed.
• The position of the index ring will limit the water temperature at the mixer outlet.
• To access the cartridge, remove the control lever by removing the cover cap, unscrew the screw using
a 2.5mm Allen key then unscrew the cover cap from the mixer body.
MAINTENANCE
• Our mixers will withstand thermal and chemical shocks as described by current guidelines.
• Check the operation of the cartridge at least once a year, and more frequently if necessary.
In case of malfunction, replace the cartridge.
• Across all mixers, the torque required to hold the cartridge in the mixer body should be between 8
and 10 Nm to avoid leaks.
EN