5.4
Disabling some of the functions
Each different function charger, inverter and transfer can
be disabled. This is useful for specifi c applications witch
required to disable some of these tree functions.
If you press the button
can have the access to the different pos-sibilities shown
in the following diagram.
In programming mode the display show only the different
types of program with the three DEL
to each functions. To change the type of programming
press shortly the button
function use according table below.
After 10 seconds the Inverter 1600 Pro exits the
programming mode and load the new change.
In user mode, the disabled functions are displayed by
blinking LED. So you can see in witch mode is disabled.
6

Maintenance

Apart from the periodic controls mentioned for the
connections, the Inverter 1600 Pro does not need any
maintenance.
Keep the appliance clean and from time to time wipe it
clean with a damp cloth.
Diagram of the different mode
Show an off LED
Show a blinking LED
Show a lighted LED
Tab. 5.4: Diagram of the different mode
02.2008
more than 2 seconds, you
-
and
until your reach to the right
All the functions are enabled.
This is the factory setting.
The inverter is disabled. Only the transfer switch and the charger
will work normally. Charger and transfer switch are disabled. the in-
verter will work continuously even if there is a cor-rect AC voltage
at the input
Inverter and charger are both disabled.
Only the transfer switch function is enabled in input voltage and
frequency is OK.
231 575
35