COMMISSIONING

7
Commissioning
7.1

Alignment

en
7.2

Check the application conditions

26
O P E R A T I N G I N S T R U C T I O N S | WTL16 / WTS16
Table 11: Test
WTL16, WTS16P: Align the sensor with the object. Select the position so that the red
emitted light beam hits the center of the object. It is important to ensure that the
optical opening (front screen) of the sensor is completely clear
NOTE
For WTS16: If the objects are detected from above, we recommend installing the sen‐
sor at an angle in order to prevent total reflection by a reflective surface,
figure
24.
Table: Alignment
WTL16
Figure 15: Alignment
WTL16, WTS16 are photoelectric proximity sensors with background suppression.
Depending on the remission of the object to be detected, and perhaps the background
behind it, a minimum distance (y) between the set sensing range (x) and the back‐
ground is to be maintained.
Test → M
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
[see
WTS16
8020347.1DS6/2021-11-24 | SICK
Test → L+
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
table].
see figure 21
-
Subject to change without notice