Commissioning - SICK HTB18 Instrucciones De Operación

Ocultar thumbs Ver también para HTB18:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 121
7

Commissioning

8017850.16K9 | SICK
Subject to change without notice
-xxxxxK
Q1 = L.ON
2
1
L/D Selection Switch in in the "D" Dark Switching position
2
L/D Selection Switch in in the "L" Light Switching position
1
Alignment
Sensor with red light:
Align sensor on object. Select the position so that the red emitted light beam hits the cen‐
ter of the object. You must ensure that the optical opening (front screen) of the sensor is
completely clear [see
figure
Figure 2: Alignment
2
Sensing range
Check the application conditions: Adjust the sensing range and distance to the object or
background and the remission capability of the object according to the corresponding dia‐
gram [see
figure
3] (x = sensing range, y = transition range between the set sensing range
and suppression of the background as a % of the sensing range (object remission/back‐
ground remission)). Remission: 6% = black 1, 18% = gray 2, 90% = white 3 (referring to
standard white as per DIN 5033). We recommend making the adjustments using an object
with a low remission.
The minimum distance (= y) for background suppression can be determined from diagram
[
figure 3
1] as follows:
Example: x = 100 mm, y = 10 => 10% of 100 mm = 10 mm. That is, the background is
suppressed at a distance of > mm from the sensor.
HTB18:
% of sensing range
25
20
15
6%/90%
18%/90%
10
1
2
5
0
0
50
100
150
(1.97)
(3.94)
(5.91)
Figure 3: HTB18, % of sensing range
2].
x = 100 mm, y = 10 mm
(= 10% of 100 mm)
1
90%/90%
2
3
3
200
250
300
A = detection distance (depending on
(7.87)
(9.84)
(11.81)
Distance in mm (inch)
object remission)
B = adjustment range
COMMISSIONING
white back-
ground (90%)
x
y
5 20
150
3 20
150
200
3 20
150
A
B
7
300
17
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Htb18l

Tabla de contenido