Commissioning; Alignment - SICK WSE16 Manual Del Usuario

Ocultar thumbs Ver también para WSE16:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
6
ADDITIONAL FUNCTIONS
en
7

Commissioning

7.1

Alignment

26
O P E R A T I N G I N S T R U C T I O N S | WSE16
Table 14: Alarm / Health
Test input
Test input: The sensors (WSO16P, WSO16I) feature a test input ("TI" or "Test" on
the connection diagram
[table
therefore, check that the sensor is functioning correctly: If female cable connectors with
LED indicators are used, you have to ensure that the TI is assigned accordingly.
It is important that there is no object between the sender and receiver; activate the test
input (see the connection diagram
The send LED is shut down or the detection of an object is simulated. Refer to
to check the function. If the switching output fails to behave in accordance with the
graphic, check the application conditions.
Table 15: Test
WSO16P: Align the sender with the receiver. Select the position so that the red emitted
light beam hits the receiver. Tip: Use white paper or a reflector as an alignment aid. The
sender must have a clear view of the receiver, with no object in the path of the beam
[figure
10]. You must ensure that the optical openings (front screen) of the sensors are
completely clear.
Alarm (≤ 100 mA)
+ (L+)
Alarm
‒ (M)
+ (L+)
Alarm
‒ (M)
2], which can be used to switch the sender off and,
table
2).
see „Troubleshooting", page
Test → M
+ (L+)
Test
‒ (M)
+ (L+)
Test
‒ (M)
Health (≤100 mA)
+ (L+)
Health
‒ (M)
+ (L+)
Health
‒ (M)
table 7
30.
Test → L+
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
8020353.1DS6/2021-11-24 | SICK
Subject to change without notice
Tabla de contenido
loading

Tabla de contenido