Fault
The motor hums but does
not start
Cause
• A phase is missing (in
three phase models).
• Lows voltage.
• High pressure pump is
blocked.
Repair
• Contact an authorised
service centre.
• Contact an authorised
service centre.
• Contact an authorised
service centre.
Fault
The motor stops suddenly
or after a while
Cause
• The
switch is on because of in-
sufficient mains voltage.
Repair
• Check the value of the
mains voltage.
• Contact an authorised
service centre.
Fault
When the lance is turned
on pressure values de-
crease and increase
Cause
• The
clogged or deformed.
• Either boiler coil or lance
are clogged with lime-
stone.
Repair
• Either clean it or replace it.
• Descaling.
Fault
To much vibrations at the
delivery
Cause
• The pressure tank is run
down.
• The valve are worn out or
dirty.
77000180-03 man NPX4 12l.indd 27
All manuals and user guides at all-guides.com
motor-protecting
nozzle
is
either
Repair
• Check the pressure in the
tank.
• Check and/or replace.
Fault
The pump does not reach
the fixed pressures
Cause
• The pump sucks air.
• The valves are worn out.
• The setting valve area is
worn out.
• The nozzle is unsuitable or
worn out.
• The seals are worn out.
Repair
• Check the suction pipes.
• Check and/or replace.
• Contact an authorised
service centre.
• Contact an authorised
service centre.
Fault
Irregular pressure fluctua-
tions
Cause
• The suction and/or deliv-
ery valves are worn out.
• Presence of foreign mat-
ters in the valves, which
generate bad functioning.
• Air suction.
• The seals are worn out.
Repair
• Check and/or replace.
• Check and clean the re-
place.
• Check the suction pipe.
• Check and/or replace the
seals.
Fault
Pressure leakage
27