Icon
*
Internal tests performed within the safety limits of the ABEK filter using the test concentrations indicated
in Table 1 (flow 30 l/min, as per concentrations indicated).
Table 1
Performances EN 403
Gas
Acrolein [C
H
O]
3
4
Hydrogen chloride [HCl]
Hydrocyanic acid [HCN]
Carbon monoxide [CO]
Powder
Sodium chloride [NaCl]
ABEK Performances
Gas
Cyclohexane [C
H
]
6
12
Chlorine [Cl
]
2
Hydrocyanic acid [HCN]
Hydrogen sulphide [H
Sulphur dioxide [SO
Ammonia [NH
]
3
3. LIMITS OF USE
Use only if the surrounding air has an oxygen content volume ranging between 17 and 21%.
These devices are disposable.
Users wearing beard and sideburns or having deep scars may not achieve perfect sealing between the
mask and the face.
Users with long hair must make sure to completely cover it with the hood to ensure sealing.
These devices are not recommended for users having narrow neck (circumference < 260 mm, such
as children), since the necessary sealing could not be achieved.
The presence of eyeglasses could make it difficult to wear the hood. It is recommended to take
them off before using the device.
Since the hood filters contain a catalyst, under certain conditions the user could experience an
increase in the temperature of the air inhaled. This does not affect the performance of the filter
and the health of the user
4. USE
4.1. Before use
Check the package before use. Do not use the respirator if the seal seems compromised.
Do not use the respirator if the bag is opened or damaged.
Always check the expiry date on the label on the bag.
4.2. Use (See Fig.1, 2, 3)
Open the bag by gripping with one hand the part marked with the "SPASCIANI" logo and pull
strongly downward with the other hand until the sealed part opens completely, as shown in
Fig.1. Should the bag not get opened the first time, grasp directly the flap of the bag and open.
Pull out the hood by the fabric; avoid pulling by the valve or by the elastic strap; follow the
indications given shown in Fig.2.
Wear the hood as shown in Fig.3: enlarge the elastic collar using both hands; position and pull the
hood over the head until it fits properly.
No special adjustment is required since the elastic strap causes the half‐mask to adhere to the face
of the user. If the mask is not correctly positioned, grasp it by the filter and pull forward to position
Device type
Fire escape protective
hood H 900 CO P
Combined fire and
industrial accidents
escape protective hood
H 900 ABEK CO P
100 ppm
1000 ppm
2500 ppm
2500 / 5000 / 7500 / 10000
ppm
Requirement EN 403
< 6%
2500 ppm
2500 ppm / 1000 ppm
2500 ppm
S]
2500 ppm / 10000 ppm
2
]
2500 ppm
2
2500 ppm
Filter type
Fire emergency filter
902 CO P
Fire emergency filter
902 ABEK* CO P
Concentrations
Concentrations
Certification
EN 403:2004 (M)
EN 403:2004 (M)
Duration
> 15 min
> 15 min
> 15 min
> 15 min
Penetration
< 6%
Duration
8 min
6 min / 17 min
> 15 min
> 15 min / > 5 min
> 15 min
> 15 min
Pg. 6/24