3. Recommendations for Installation

3.1 - General Notes

Although the construction and operation of every counter is controlled on the factory floor, this does not invalidate the possibility
that damage may be caused during transportation. Thus upon reception we advise that the general condition of the counters
should be verified.

3.2 - Placement

Remove the packaging or pallet carefully so that the equipment's surfaces are not damaged. Remove the PVC inox
protection.
The appliance should be installed away from heat sources (ex: heating appliances) and direct sunlight.
The bottom right/left side has vents with openings that should never be covered or blocked - must be guaranteed free space to
this areas, assuring a good air circulation.
To ensure that the appliance functions well, it should always be correctly levelled and slightly inclined to the back, to make sure
that the doors close perfectly. Small differences in level can be compensated for by regulating the feet.
In the models not equipped with automatic systems for the evaporation of condensation waters, there is a collecting tray that must
be placed underneath the appliance and which should be emptied regularly.

3.3 - Installation

Installation should be carried out with the following standards always being borne in mind:
Regulations referring to the construction of the buildings and fire-precautions.
Regulations in force concerning accident prevention.
European Union Standards that may be in force.
The table is supplied with a plug in accordance with current standards of practice and with electricity supply power cable
according to the regulations with a length that is sufficient to allow connection to the electricity current.
The electrical socket should be easily accessible and organised so that maximum consumption is available (see data from the
Table of Technical Terms). The socket should be EARTHEN.
Never use plugs or sockets without earth, nor use adapters or extension wires.
For direct connections to the network, a fuse switch should always be installed in accordance with international regulations.
3.4 - Substitution of the Electricity Supply Cable
Pull the power cord from the plug
The terminal board is in the compressor compartment. Remove the cover of the terminal board.
Loosen the fastening device from the cord at the bottom of the compartment.
To remove the conductors, loosen the terminals and replace the cable. The new one must have at least the characteristics on
the Technical Data Table. The earth wire must be longer than the phase and neutral wires.
The Ensure that the supply cable is not subject to traction and that it does not contain coils or knots that could create heat.
The manufacturer declines any responsibility both for the operation, and for damage or losses caused, which result from lack of
observing recommendations in this instruction manual.
4. Recommendations for the User
Refrigerated counters were conceived in order to conserve food during short periods of time and for food products in general.
In order to ensure that the machine is operating properly it is necessary to follow the following instructions:
Children should be supervised to ensure that they do not play with the device.
Avoid opening the doors and drawers as much as possible.
When putting in food, make sure that there is good natural circulation of air inside.
MNS00024_03
TEC
INSTRUCTIONS MANUAL
.
Power cord:
- type
- Nominal section
- Manufacture code (normal)
HO5VVF
3 x 1.5 mm2
43001004
(England)
43001001
N.º
MNS00024_03
10/45
Tabla de contenido
loading

Este manual también es adecuado para:

46710110001-0-n-t

Tabla de contenido