STD
SLIM
Note: Menu selection indicates current configuration (ENABLED or DISABLED).
TORQUE THEN ANGLE MODE
Torque THEN Angle mode is setup by first setting a target torque and units then a target angle before
selecting Torque THEN Angle mode. In Torque THEN Angle mode, when applied torque reaches target
torque, wrench automatically switches to angle mode for angle measurement. Progress lights indicate
applied torque progress while torque is measured and angle when angle is measured. If torque is below
target torque when angle reaches target angle, green progress lights will not turn on and if angle exceeds
maximum angle, red progress lights turn on indicating a potential problem with fastener.
1. From target torque screen, use UP/DOWN buttons to set target torque and UNITS button to select
torque measurement units then press ENTER button.
2. Angle target screen is displayed. Use UP/DOWN buttons to set target angle then press ENTER button.
3. Torque THEN Angle mode screen is displayed.
4. Apply torque until target is reached then rotate wrench to target angle.
STD
SLIM
27