2
Main switch
6.1
Quick-release clamp for fastening the suction
plate
3.2 Operating Elements
•
The main switch (2) is used to switch the vacuum generator on and off.
•
The control lever (8) is used to release the load. The control lever can only be pulled with the lock(8.2) is pressed
down.
3.3 Vacuum Generator
The vacuum is generated by an electrical vacuum blower (3). The vacuum generator is designed for airtight loads.
3.4 Suction Plates
The suction plate is not included in the scope of delivery. It is used to pick up the load. The suction plate to be used de-
pends on the load (weight, geometry and surface properties).
Use only suction plates from the manufacturer Probst with carrying capacity labels that indicate without a doubt a maxi-
mum carrying capacity at a vacuum of -0,2 bar. If the situation is unclear, the lifting device and suction plate may not be
put into operation. Contact Probst GmbH.
Standard suction plates are not suitable for handling glass sheets.
The suction plate (6) must be attached to the main body (7) with the quick-release clamps (6.1).
The maximum permitted lift capacity of the suction plate determines the maximum permitted lifting capacity
of the entire lifting device (see the lift capacity plate on the suction plate).
52700015 / 52700016 / 52700017 / 52700018 / 52700019 / 52700020
5
Operator handle
7
Main body
Product description
15 / 41