2.12.1 Coaxial duct
Coaxial accessories
Description
Coaxial duct kit
Extension W. 1000 mm
Extension W. 500 mm
Vertical extension W. 140 mm with
smoke analysis take-off point
Adapter for Ø 80/125 mm
Additional 90° curve
Additional 45° curve
Tile with joint
Roof outlet terminal W. 1284 mm
Load loss - Equivalent lengths
Model
90° curve
45° curve
Minimum-Maximum Lengths
Duct Length Ø 60/100
W Hori-
Model
zontal (m)
Min. Max. Min. Max. Min. Max. Min. Max.
Brava One
-
6
HE 25
Brava One
-
5
HE 30
2.12.2 Separate ducts (split pipe system Ø 80mm)
Constructing outlets for separate ducts indicates the use of
the "air-smoke split pipe system". This is to be ordered se-
parately from the boiler and when connected to the other ac-
cessories, from those listed in the table below, completes the
smoke-outlet/ combustion air inlet assembly.
Separate accessories
Description
Air-smoke split pipe system (without
take-off point)
Air-smoke split pipe system (with
take-off point)
90° curve M-F (6 pieces)
90° curve M-F (with take-off point)
M-F 80/60 reduction
Extension W. 1000 mm (6 pieces)
Extension W. 500 mm (6 pieces)
Extension W. 135 mm (with take-off
point)
Wall outlet terminal
Internal and external ring nut kit
Inlet terminal
45° curve M-F (6 pieces)
Manifold
Tile with joint
Roof outlet terminal W. 1390 mm
Inlet/outlet fitting Ø 80/125 mm
66
All manuals and user guides at all-guides.com
Code
Ø 60/100
Ø 80/125
mm
mm
8096250
8096253
8096150
8096171
8096151
8096170
8086950
-
-
8093150
8095850
8095870
8095950
8095970
8091300
8091300
8091205
8091205
Leq (linear metres)
Ø 60/100
Ø 80/125
mm
mm
1,5
2
1
1
Duct Length Ø 80/125
H Vertical
W Hori-
H Vertical
(m)
zontal (m)
(m)
1,3
8
-
12
1,2
15
1,3
7
-
10
1,2
13
Code
Diameter Ø
Diameter Ø
60 (mm)
80 (mm)
8093060
-
-
8093050
8089921
8077450
8089924
-
8089923
-
8089920
8077351
-
8077350
-
8077304
8089541
8089501
8091510
8091500
8089540
8089500
8089922
8077451
8091400
8091300
8091204
-
8091210
Split pipe system
2
1
KEY:
Split pipe system with take-off point
1
Air inlet
2
3
Smoke outlet
Take-off point for smoke analysis
4
m
CAUTION
– The maximum total length of the ducts , obtained by
adding the lengths of the inlet and outlet pipes, is
determined by the load losses of the individual ac-
cessories used and must not exceed 15 mm H2O .
– The total extension must not in any case exceed 50 m
even if the total load loss is less than the maxi-
mum which can be applied.
Load loss accessory Ø 60 mm
Description
Code
Brava One HE 25
Inlet
Air/smoke split
8093060
2,5
pipe system
90° curve MF
8089921
0,4
45° curve MF
8089922
0,35
Horizontal exten-
8089920
0,4
sion W. 1000 mm
Vertical extension
8089920
0,4
W. 1000 mm
Wall outlet ter-
8089541
_
minal
Wall inlet terminal 8089540
0,5
Roof outlet termi-
8091204
0,8
nal (*)
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
NB:
for the boiler to operate correctly it is necessary that a
minimum distance of 0.50 m of the duct is respected with a
90° inlet curve.
EN
3
4
Fig. 14
Load loss (mm H2O)
Brava One HE 30
Outlet
Inlet
Outlet
0,5
2,5
0,5
0,9
0,5
1,1
0,7
0,45
0,9
0,9
0,5
1,1
0,6
0,5
0,7
1,2
_
1,4
_
0,8
_
0,1
1,1
0,15