2.12.1 Coaxial Duct; Separate Ducts (Split Pipe System Ø 80Mm) - Sime BRAVA ONE HE 25 Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para BRAVA ONE HE 25:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2.12.1 Coaxial duct

Coaxial accessories
Description
Coaxial duct kit
Extension W. 1000 mm
Extension W. 500 mm
Vertical extension W. 140 mm with
smoke analysis take-off point
Adapter for Ø 80/125 mm
Additional 90° curve
Additional 45° curve
Tile with joint
Roof outlet terminal W. 1284 mm
Load loss - Equivalent lengths
Model
90° curve
45° curve
Minimum-Maximum Lengths
Duct Length Ø 60/100
W Hori-
Model
zontal (m)
Min. Max. Min. Max. Min. Max. Min. Max.
Brava One
-
6
HE 25
Brava One
-
5
HE 30
2.12.2 Separate ducts (split pipe system Ø 80mm)
Constructing outlets for separate ducts indicates the use of
the "air-smoke split pipe system". This is to be ordered se-
parately from the boiler and when connected to the other ac-
cessories, from those listed in the table below, completes the
smoke-outlet/ combustion air inlet assembly.
Separate accessories
Description
Air-smoke split pipe system (without
take-off point)
Air-smoke split pipe system (with
take-off point)
90° curve M-F (6 pieces)
90° curve M-F (with take-off point)
M-F 80/60 reduction
Extension W. 1000 mm (6 pieces)
Extension W. 500 mm (6 pieces)
Extension W. 135 mm (with take-off
point)
Wall outlet terminal
Internal and external ring nut kit
Inlet terminal
45° curve M-F (6 pieces)
Manifold
Tile with joint
Roof outlet terminal W. 1390 mm
Inlet/outlet fitting Ø 80/125 mm
66
All manuals and user guides at all-guides.com
Code
Ø 60/100
Ø 80/125
mm
mm
8096250
8096253
8096150
8096171
8096151
8096170
8086950
-
-
8093150
8095850
8095870
8095950
8095970
8091300
8091300
8091205
8091205
Leq (linear metres)
Ø 60/100
Ø 80/125
mm
mm
1,5
2
1
1
Duct Length Ø 80/125
H Vertical
W Hori-
H Vertical
(m)
zontal (m)
(m)
1,3
8
-
12
1,2
15
1,3
7
-
10
1,2
13
Code
Diameter Ø
Diameter Ø
60 (mm)
80 (mm)
8093060
-
-
8093050
8089921
8077450
8089924
-
8089923
-
8089920
8077351
-
8077350
-
8077304
8089541
8089501
8091510
8091500
8089540
8089500
8089922
8077451
8091400
8091300
8091204
-
8091210
Split pipe system
2
1
KEY:
Split pipe system with take-off point
1
Air inlet
2
3
Smoke outlet
Take-off point for smoke analysis
4
m
CAUTION
– The maximum total length of the ducts , obtained by
adding the lengths of the inlet and outlet pipes, is
determined by the load losses of the individual ac-
cessories used and must not exceed 15 mm H2O .
– The total extension must not in any case exceed 50 m
even if the total load loss is less than the maxi-
mum which can be applied.
Load loss accessory Ø 60 mm
Description
Code
Brava One HE 25
Inlet
Air/smoke split
8093060
2,5
pipe system
90° curve MF
8089921
0,4
45° curve MF
8089922
0,35
Horizontal exten-
8089920
0,4
sion W. 1000 mm
Vertical extension
8089920
0,4
W. 1000 mm
Wall outlet ter-
8089541
_
minal
Wall inlet terminal 8089540
0,5
Roof outlet termi-
8091204
0,8
nal (*)
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
NB:
for the boiler to operate correctly it is necessary that a
minimum distance of 0.50 m of the duct is respected with a
90° inlet curve.
EN
3
4
Fig. 14
Load loss (mm H2O)
Brava One HE 30
Outlet
Inlet
Outlet
0,5
2,5
0,5
0,9
0,5
1,1
0,7
0,45
0,9
0,9
0,5
1,1
0,6
0,5
0,7
1,2
_
1,4
_
0,8
_
0,1
1,1
0,15