ENGLISH
2) Press the set point button to display the current
set point temperature.
3) Keep pressing the set point button, and push the
temperature control button until the temperature
display window shows the desired temperature.
The cabinet temperature is adjustable between
-0°C and 16°C [or -6°C and 12°C (-F type)] for the
refrigerator and between -7°C and -25°C for the
freezer.
4) The displayed cabinet temperature is adjusted
to be almost equal to the temperature at the
center of the cabinet without foods. But it can be
different from the actual temperature depending
on arrangement of stored foods, frequency of door
opening or measuring points.
Frame Heater
Button
Reset Button
Set Point Button
Temperature
Display Window
Fig. 8
[d] FRAME HEATER
The front frame is provided with a built-in heater to
prevent condensation. It is factory-adjusted to "low".
If condensation forms on the front frame, the frame
heater can be adjusted to "high".
Press the frame heater button on the operation panel
for more than 3 seconds. The lamp will illuminate
and the frame heater will be adjusted to "high".
To change the setting to "low", press the frame
heater button for more than 3 seconds. The lamp will
go out and the frame heater will be set to "low".
[e] DEFROST
The refrigerator/freezer automatically defrosts the
evaporator every 6 hours. For the refrigerator, the
temperature display window shows the cabinet
temperature and "dF" alternately during defrost
cycle. For the freezer, the temperature display
window shows "dF" during defrost cycle.
To start a manual defrost cycle, press the manual
defrost button for more than 5 seconds. The next
defrost cycle will begin in 6 hours.
[f] LOCK
The door lock is provided on the top or side of the
door. To lock the door, push and turn the key. The
lock plate in the door lock will fit into the lock bracket
in the door.
[g] SHUT DOWN
1) Before shutting down the unit, move the stored
foods into another refrigerator/freezer.
2) Unplug the unit or disconnect the main power
supply.
3) When preparing the unit for long storage, clean
the cabinet interior and door gaskets, dry them
thoroughly and store the unit in a dry place.
III. MAINTENANCE AND CLEANING
Manual Defrost
INSTRUCTIONS
Button
Temperature
1. B e f o r e c a r r y i n g o u t a n y c l e a n i n g o r
Control Button
maintenance operations, unplug the unit.
2. D o n o t t o u c h o r w e t t h e m a c h i n e
compartment parts. This could result in
failure or breakdown.
1. INTERIOR, EXTERIOR, SHELF
* Clean the interior and exterior at least once a
week for sanitary use. The unit can be moved by
unlocking the casters.
* Clean off the interior and exterior with a soft cloth
soaked in cold or warm water containing the proper
amount of neutral cleaner and wrung dry. Do not
use a water jet to clean the machine compartment.
* Chemical agents other than neutral cleaner might
cause damage to the interior and exterior surfaces.
* Any remaining detergent will damage metal or
plastic surfaces. Use a soft cloth dampened with
warm water to wipe it off.
* Do not use the following items. They could damage
painted or plastic surfaces:
6
IMPORTANT
Fig. 9