Accuracy: DM-100 (cont'd)
DC Voltage
Range*
± (0.5% + 0.2 mV)
320.0 mV
± (0.5% + 0.002 V)
3.200 V
± (0.5% + 0.02 V)
32.00 V
320.0 V
1000 V
Resistance
Range*
320.0 Ω
3.200 kΩ
32.00 kΩ
320.0 kΩ
3.200 MΩ
32.00 MΩ
Typical open circuit voltage: 1.5V
* In autorange mode, ranges change at approximately 3200 counts.
In manual range mode, range extends to 3400 counts.
Diode Test
Test Current (Typical): 1.5 mA
Open Circuit Voltage: Less than 3.1 VDC
Continuity
Threshold: Tone sounds if the measured resistance is less than approximately 30 Ω.
Response Time: Approximately 100 ms
All manuals and user guides at all-guides.com
Accuracy
± (0.5% + 0.2 V)
± (0.5% + 2 V)
Accuracy
± (1% + 0.4 Ω)
± (0.75% + 0.003 kΩ)
± (0.75% + 0.03 kΩ)
± (0.75% + 0.3 kΩ)
± (1% + 0.003 MΩ)
± (2% + 0.05 MΩ)
Input Impedance
over 1000 MΩ
10 MΩ