Ferroli MACH Instrucciones De Uso página 297

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MACH
Exclude hot water tank (economy)
Hot water tank temperature maintaining/heating can
be excluded by the user. If excluded, domestic hot
water will not be delivered. The hot water tank can be
deactivated by the user (ECO mode) by pressing the
eco/comfort button (detail 10 - fig. 1). In ECO mode
the display activates the symbol
COMFORT mode, press the eco/comfort button (de-
tail 10 - fig. 1) again.
Information
From the main screen (Home - detail A of fig. 8), press contextual button 2. Access the screen for choosing the module
with information to view.
Select the module using buttons 5 and 7 (detail B and C of fig. 8) and then press OK.
23°C
--
Thursday 9 Jan. 2014 11:30:43
Then use the "Menu Navigation" buttons to display the following values:
1
Heating demand
2
Heating circulating pump
3
Heating 3-way valve
4
DHW 3-way valve
5
Standby time
6
T Delta protection
7
Flame Supervisor
8
Heating sensor 1 (Flow)
9
Heating sensor 2 (Safety)
10
Return sensor
11
DHW sensor
12
External probe
13
Fume sensor
14
Cascade heating sensor
15
Fan frequency
16
Burner load
17
System water pressure
18
Modulating circulating pump
19
Cascade modulating circulating pump
20
Ionization current
21
Input 0-10Vdc
22
Heating adjustment temperature
23
Power level adjustment 0-10Vdc
EN
. To activate
v. 04
v. 04
v. 04
v. 04
to confirm
fig. 8
OT - OpenTherm control request
TA - Room thermostat request
0-10Vdc - 0-10Vdc signal request
TA2 - Second room thermostat request
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
°C
°C
°C
°C
°C
°C
°C
Hz
%
1.4bar = ON, 0.0 bar = OFF
%
%
uA
Vdc
Setpoint (°C)
Setpoint (%)
cod. 3541V120 - Rev 00 - 09/2021
23°C
32°C
Thursday 9 Jan. 2014 11:30:43
fig. 7- Economy
v. 04
v. 04
v. 04
v. 04
to confirm
297
Tabla de contenido

Solución de problemas

loading

Tabla de contenido