Waeco CAB-40 Manual Del Usuario página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
manual 4445100023_a.qxd
Replace of gas bottles
• Only replace the gas bottles under good ventilation. Make sure that no ignition sour-
ces are nearby. Close the valve of the gas bottle completely.
• Screw the pressure control valve off the bottle
• Check condition of the gas line. Exchange the gas line in case the material is brittle
or porous.
• Screw the pressure control valve tight onto the new bottle.
Burner ignition
• Open the gas bottle valve. Make sure that the thermostat for 230-V operation is in
"0"-position and that the plug (battery) is not connected. Turn the gas knob to max.
(big flame) and keep pressed for 10 seconds to displace any air out of the gas line.
• As the gas knob is pushed in, press the ignition button several times if required until
the flame is burning, wait 15 seconds and then release the gas knob.
In case the flame does not ignite, repeat the ignition process. The device is equip-
ped with a flame protection. When the flame expires, the gas supply
cuts off.
In case it is not possible to ignite with the spark generator because of high
humidity, the gas burner can be ignited with a match through the opening
(see fig. 2, page 1) in the backside. To switch off the gas operation always
close the bottle valve first and then turn the gas handle to "0"-position.
Important
Make sure that the connecting cables are a safe distance from the burner
during gas operation of the coolbox. Check at regular intervals the that the
gas hose and the connections are in good condition.
Mains voltage operation 230 volt
• Put the safety plug into an according to instructions installed safety plug.
• Move the thermostat button ton position "max" and wait until the temperature of the
coolbox has dropped down. Thereupon adjust the thermostat knob to the tempera-
ture desired.
• To switch off the coolbox turn thermostat button to "0" and pull the mains plug after
switching off supply.
Operation with battery power
The electric line between battery and fridge must be saved by a fuse: at 12 V max. 15
A.
Cable size:
2,5 mm
2
at battery cable length up to 2,5 m
4,0 mm
2
at battery cable length up to 4,0 m
Make sure that the thermostat button is in position "0" at 230-V operation.
• Put the plug into the socket of the cigarette lighter. Poling as given.
• For switch-off, pull the plug out of the socket.
Separate the coolbox from the battery at the motor shut-down, otherwise battery
discharges. An adjustment of the thermostat is not possible during battery operation.