Dimplex CEL50 Manual Del Propietário página 11

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fireplace Installation
5. Unscrew the two wire
connectors inside the electrical
box and separate the wires
(Figure 5).
6. Remove the one Phillips screw
that attaches the junction box
cover to the fireplace chassis
(Figure 5) from inside.
7. From the back of the fireplace,
remove the remaining three
Phillips screws which hold the
junction box to the fireplace
chassis (Figure 6).
8. Pull the junction box and
power cord out the front of the
fireplace.
9. Replace removed junction
box cover with the supplied
hard-wire cover replacement
(Figure 7) and install using
screws removed in steps 6
and 7.
10. Leaving a minimum of 3"
(7.6 cm) of slack, route the
power supply through the hole
in the alternate junction box
cover and secure with a wire
clamp (not supplied).
11. Connect the black wire (live)
from the unit to the black wire
from the power supply using
one of the wire connectors
removed in step 5 (Figure 8).
Figure 8
Black live
wires
White neutral wires
Figure 7
12. Connect the white wire (neutral)
from the unit to the white wire
from the power supply using
the second wire connector from
step 5 (Figure 8).
13. Attach green grounding wire
to hard wire cover cover with
provided grounding screw.
Place wire in-between screw
and lock washer and tighten.
Wires to
controls
Hole for
Ground Screw
11