Range control
This baby nursery is equipped with an optical and acoustic range control system. The paren-
tal unit checks two-way contact at regular intervals. When range is exceeded or interruption
of connection due to other breakdowns, the LED status starts blinking red on the parental
unit and a signal tone sounds at regular intervals.
When checking the range, youc can choose automatic or manual range control or turn it off.
To do so, press the
button 3× on to the parental unit until
of the display. Current settings (available only on the parental unit), AU, Pb, or oF flashes to
the right of the display. Press / to select either AU for automatic range control or Pb,
if you need to manually check the range. Select oF to completely turn off the range control
function. To save the settings, briefly press the PTT button or wait for 5 seconds.
1) automatic range control (AU)
Automatic range control is automatically activated in baby monitor mode. This function au-
tomatically, checks in minute intervals, whether the child and parental unit are out of reach.
The parental unit sends a signal to the child unit. This repeats the signal. If the parental unit
does not receive a reply for more than 2 minutes, the radio connection is interrupted. The
reason may be that both devices are out of reach, that the batteries of the other device are
too weak, that the device is turned off, or that the set radio channel is faulty. While connec-
tion is active, the
symbol is constantly displayed. When the connection is interrupted,
the symbol flashes and 5 beeps sound, which means that the child unit is not responding
to the signal. Once the two devices are connected, the symbol appears permanently after
two minutes.
2) manual reach control (Pb)
You can also check manually if you are finding the child unit within range. For this, the reach
function must be set to Pb on the parental unit. Press the
seconds. The child unit will answer your question and the parental unit will react with a
melody. Now you can be sure that both devices are within range.
32
appears on the left side
-button and wait for several
3) deactivation of range control (oF)
Range control can be deactivated if it is not needed.
Warning: We recommend that if you know the surrounding environment and have tried the
baby monitor several times in this environment, you re-set the range control to manual, or
to deactivate it. If you want to minimize radiation and energy consumption (ECO mode),
deactivate range control or use manual range control.
Display of noise level (parental unit)
The visual control of the noise level in a child's room is provided 3 LEDs above the display.
Press
button 4×, until FL appears to the right of the display. The current setting, AU or
01-03 is flashing on the right side of the display.
Pressing / buttons will change the setting.
• If you wish to activate visualisation of noise level, select AU. If the baby cries little, only
1 LEDs light up. If the baby cries louder, 2 LEDs light up. If the baby cries very loud, all 3
LEDs light up.
• If you select 01, 02 or 03, the number of LEDs lighting up does not depend on the baby's
loudness. The selected number of LEDs will always light up.
Night light (baby unit)
The night light integrated in the child unit creates a soothing environment for your child
thanks to its warm light. Night light can be activated only on the child unit.
Press
button 4×, until FL appears to the left of the display. Current settings, oF or 01-03
flashes t0 to the right of the display. If you wish to choose among 1-3 LED, press / but-
tons and select 01-03. In order to turn off all LED, select oF.
Switching over to „baby monitor" operating mode
This step is only necessary in the case that the devices were previously used as as PMR446