6.3
Remove the three Shipping Spacers and Screws to free
the Fan Motor Hub for installation of the Ceiling Fan Blade
Assemblies, as follows:
Rotate the Fan Motor Hub to align the Light Fixture Plate
Access Hole over the Shipping Spacer Screw (Figure 19).
Remove and Discard the three Shipping Spacer Screws
and Shipping Spacers (Figure 19).
6.4
NOTE: Your Ceiling Fan will operate with the following
Blade Select Blades (Sold Separately):
B77, B78, B79, B90, B91, B92, B97, B100, B101, B102,
B103, B107, B108, B109, G44, G54, & G60.
Mount the Fan Blade (sold separately) using the Four
#10-24 x 12mm Washer Head Screws and Four Flat
Washers (supplied in parts bag) to secure Flange to Blade
(Figure 20).
Repeat for the remaining Four Blades.
Make sure all Screws are tighten securely in the Fan Blade
and Flange.
NOTE: Some Accessory Blades are supplied with
shorter Screws. These shorter Screws MUST be used
to assemble the Blades to Flanges.
6. Final Assembly
(Continued)
SHIPPING SPACERS
SCREWS (3)
Figure 19
BLADE FLANGE
Figure 20
13
SHIPPING
SPACERS (3)
FAN MOTOR
HUB
LIGHT FIXTURE PLATE ACCESS HOLE
#10-24 x 12mm
WASHER HEAD
SCREWS (4 per blade)
FLAT WASHERS
(4 per blade)
FAN BLADES
(sold separately)