Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7 Technical data

Powermeter EduTrainer
technical data
®
Auxiliary energy (line power)
Backup fuses for
auxiliary and measurement voltages
Connection
Protective grounding terminal
Protection class
Overvoltage category
Contamination level
Operating temperature range
Degree of protection
Dimensions (H x W x D)
Weight
Operating position
Measured variables
Nominal current
Overload capacity
Nominal voltage
Types of connection
8108196
© Festo Didactic
1 AC 110...230 V/20 VA/50/60 Hz
Max. 16 A B characteristic
Safety laboratory cables per EN 61010-031, min. conductor cross-section: 1 sq. mm
PE+ contact
1, operation with protective grounding
CAT II, Operation in building installations
2. Laboratory environment
15 ... 30° C
IP 20
266 x 297 x 95 mm
Approx. 2,7 kg
Table-mounted or suspended in rack
max. 5 A
10 A continuous
100 A, 5 x 1 s, 300 s interval
57.7...300 V
, 100...520 V
LN
LL
Single-phase system
Split phase (2-phase system) 3-wire, balanced load
3-wire, balanced load, synthetic test circuit (2 x U,1 x I)
3-wire, unbalanced load
3-wire, unbalanced load, Aron circuit
4-wire, balanced load
4-wire, unbalanced load
4-wire, unbalanced load, open Y
Powermeter EduTrainer
®
33
Tabla de contenido
loading