Additional Functions - SICK WSE26 Instrucciones De Operación

Ocultar thumbs Ver también para WSE26:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
6

ADDITIONAL FUNCTIONS

6
Additional functions
8
Table 5: Push-pull, PNP, NPN
PNP
Push-pull
NPN
PNP
Push-pull
NPN
Alarm
Alarm output: The sensor (WSE26) features a pre-failure notification output ("Alarm"
in the connection diagram
only ready for operation to a limited extent. The LED flashes in this case. Possible
causes: sensor is contaminated, sensor is out of alignment. In the good state: LOW (0),
if excessively contaminated HIGH (1).
Health
Health output: The sensor (WSE26) features a pre-failure notification output ("Health"
in the connection diagram
only ready for operation to a limited extent or the cable has been interrupted. Possible
causes: Sensor is contaminated, sensor is out of alignment, cable is damaged. In the
good state: HIGH (1), if excessively contaminated or in the event of cable interruption
LOW (0). The yellow LED indicator flashes in this case.
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
[see table
3]), which issues a notification if the sensor is
[see table
3]), which issues a notification if the sensor is
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
8020358.19RH / 15.01.2021 | SICK
Subject to change without notice