CAME ZT6 Repuestos Originales página 9

Ocultar thumbs Ver también para ZT6:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
Adjustment Trimmer
b
Trimmer T.C.A. = Adjusts automatic closing time from a minimum of 1 sec to a maximum of 120 sec.
Part. Op. Trimmer. = Adjusts automatic opening time from a minimum of 1 sec to a maximum of 14 sec.
Memorizing the code on the command board
1) Connect the antenna with the RG58 cable to the apposite terminals on the board.
2) The AF board should ALWAYS be inserted in
c1
when the power is off because the motherboard only recognises it when it is powered.
c2
3) Keep the CH1 key pressed on the base card and after the LED signal
lights up, send a command using the transmitter key.
The LED will fl ash briefl y to signal that the code has been memorized.
4) Perform the same procedure with the CH2 key, associating it with another transmitter key.
N.B.: if the code needs to be changed, rapeat the sequence described obove.
9
The data and information provided in this manual are to be considered susceptible to change at any time without warning, by CAME cancelli automatici s.p.a.
Tabla de contenido
loading

Este manual también es adecuado para:

3199zt6

Tabla de contenido