Cleaning The Ash Drawer; Combustion Chamber Cleaning; Smoke Conduit Cleaning - Ravelli Luna Manual De Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Rev.0 18/07/2019
Pag.72
EN
Brazier cleaning to be completed before each ignition
It is necessary to check that the brazier where combustion takes place is well cleaned and that waste or residue does not block the holes.
This will guarantee optimal combustion in the stove over time, avoiding possible overheating that could cause the paint to change colour
or the door to peel, as well as missing stove start-up.
Only a clean and precise brazier can guarantee that the thermo-stove operates optimally. During operation it is possible that deposits may
form that must be eliminated.
It is possible to recognise when the brazier needs to be cleaned! It is sufficient to check visually: cleaning must be daily, before each start-
up. For light cleaning, it is possible to leave the brazier in the stove, but if residues are difficult to remove, it is necessary to remove it from
its seat and scrape the residue.
The ash residue depends on the quality of the pellet used.
Caution: between different bags of pellet, despite being of the same brand there may be differences. These may in fact generate different
combustion conditions and therefore result in different quantities of residue.
Correct daily cleaning will allow the stove to burn in an optimal manner and have a good yield, avoiding malfunctioning that over time would
require intervention on the part of a technician to restore the machine.

Combustion chamber cleaning

To clean the ash drawer, proceed as follows:
step
action
The stove requires a simple yet frequent cleaning in order to guarantee suitable yield and regular operation. Vacuum the
1
combustion chamber every day using a bin ash vacuum, making sure that the ashes are completely cold.
1
combustion chamber
Cleaning the pellet tank
To clean the pellet tank, proceed as follows:
step
action
1
Periodically remove the wood sawdust accumulated on the bottom of the tank, using a vacuum cleaner.

Smoke conduit cleaning

! IMPORTANT
step
action
1
Open the hatches.
2
Clean the ashes, eventually use a brush or similar and reassemble everything.
Note: the hatches are equipped with gaskets, therefore, before reassembling them, make sure that the gaskets are not
worn.
Use and maintenance manual Luna
Brazier is cleaned well, with all holes
visible
This operation must be carried out by a Ravelli Assistance Centre.
Schedule this type of cleaning with the Ravelli Assistance Centre.
The smoke conduit must be cleaned every 3 months.
Brazier requiring cleaning having its
holes blocked by the ashes
2
Tabla de contenido
loading

Tabla de contenido