Troubleshooting

i
In case of transmission problems during control
unit diagnosis, please see the notes in section 3.6.
4.6.1

Diagnostic device not found

No diagnostic unit (KTS 560 / 590) was found on
establishing communication with the control unit. The
Establish a connection with
error message
the communication module and connect with
external voltage supply
wireless connection with the KTS module
displayed.
Possible causes
What to do
No external voltage
Check if the KTS module is supplied
supply.
with external voltage (power supply unit
or OBD connection cable).
The LED on/off must light up green.
KTS module not
1. Quit control unit diagnosis.
active or incorrectly
2. Launch DMC ("Start >> All programs >>
configured.
Bosch ESI[tronic] 2.0 >> ESI[tronic] 2.0
>>
settings >> KTS 5xx").
3. In DMC, check if the KTS module has
been configured and activated correctly.
4. Then, test the KTS module.
No Bluetooth
1. Plug in the Bluetooth USB adapter.
USB adapter.
2. Relaunch control unit diagnosis.
Robert Bosch GmbH
Initial commissioning | KTS 560 / 590 (KTS 5a Series) | 21 |
Error in the
or
is
(main menu) >> Hardware
4.6.2
No communication between PC/laptop and
KTS 560 / 590
Possible causes
What to do
The Bluetooth
Plug Bluetooth USB adapter into a USB
USB adapter
3.0 port.
included in the
scope of delivery
is connected to
USB 2.0 port.
4.6.3

No communication with control unit

During the control unit diagnosis, the following failure
No communication with the
indication appears:
control unit. Adapter cable connected?
Possible causes
What to do
Wrong cable has
Check whether the correct cable has
been connected.
been used.
i
If problems of a different nature occur, please
contact the ESI[tronic] Service Hotline directly.
5.

Maintenance

5.1
Cleaning
The housing of KTS 560 / 590 (KTS 5a Series) are only
to be cleaned using a soft cloth and a neutral cleaning
agent. Do not use any abrasive cleaning agent or rough
cleaning cloths.
5.2
Maintenance
The tab Customer service can be used for performing
various tests in DMC. A portion of these tests can only
be performed by customer service.
5.3
Spare and wearing parts
i
The list only contains the replacement and wearing
parts included in the scope of delivery.
Designation
Diagnostic device KTS 560
Diagnostic device KTS 590
OBD connection cable 1.5 m
<)
Power supply unit
Measuring cable red/black (KTS 590 only)
Measuring cable blue/yellow
<)
Measuring clamp black
<)
Test prods
<)
Test prods
<)
USB connection cable 3 m
<)
Parts set for mount
Case
Bluetooth USB adapter
Protective cap
<)
Wearing part
<)
en
Order number
1 687 023 667
1 687 023 668
1 684 465 881
1 687 023 736
1 684 463 945
<)
1 684 463 950
1 681 354 035
1 683 050 050
1 684 480 125
1 684 465 562
1 687 016 137
1 685 438 648
1 687 023 777
1 680 591 037
|
1 689 989 223
2021-09-24
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Kts 5901 687 023 6671 687 023 668

Tabla de contenido