Possible Problems - Campingaz Xcelerate 600 SV Instrucciones De Empleo

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
scouring pad or abrasive products).
- Remove and clean all parts of the stove and
dry them well.
- Remember to protect the appliance lid
by inserting a protective material (paper,
cardboard, ....) between the lid and the grill
hotplates.
- Store the assembly in a clean well ventilated
place.
- If the appliance has not been used for over
30 days verify that there are no spider's
webs blocking the burner tube, which can
reduce the efficiency of the appliance
or cause dangerous combustion of gas
outside the burner.
- Store the packed stove in a dry, well-
ventilated place.
2) Flexible hose or hose between the
regulator and the stove
- Check the condition of the piping periodically
and change it if it shows signs of ageing or
cracks or when national conditions require
it.
- In France, if the expiry date printed on
the flexible pipes is reached, the flexible
pipe with collars must be replace by an
assembly complying with Standard XP D
36-110.
Follow the assembly instructions supplied
with these new assemblies, whose length
must be a maximum of 1.50 m, and the
procedure described in paragraph B).
If you do not plan to use your stove for a
long period, disconnect the gas cylinder.
H - WARRANTY PERIOD
Years
2

Possible problems

The burner does not light up
- Poor gas supply
- Regulator not operating properly
- Pipe, valve, venturi tube or burner holes
obstructed
The burner does not burn smoothly or
goes out
- Check that gas is present
- Check the pipe connection
- Contact your servicing agent.
Unstable blowing flames
- New cylinder may contain air. Allow the
stove to operate and the fault will clear itself
- Residual water, following the washing of the
burner caps
- Contact your servicing agent.
Large plume of flame on the burner surface
- The
venturi
cobwebs). Clean the venturi.
- Contact your servicing agent.
Flame at the injector
- The cylinder is almost empty
- Change the cylinder and the fault will clear
itself
- Contact your servicing agent.
burning leak around a union
- Shut off the gas supply immediately
- Leaking union: tighten nuts or change pipe
- Contact your servicing agent.
Insufficient heat
- Injector or venturi tube obstructed
- Contact your servicing agent.
burning leak behind the adjustment knob
- Defective valve
- Shut down the stove
- Contact your servicing agent.
11
is
obstructed
(possibly
GB
Tabla de contenido
loading

Tabla de contenido