Conversion To A Different Type Of Gas; Commissioning; Troubleshooting; Wok - AFG 700 Serie Instrucciones Para Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
• Read this manual carefully. It provides important information
for safe installation, use and maintenance of the appliance.
• Installation, conversion to a different type of gas and applian-
ce maintenance must be carried out by qualified technicians
authorized by the manufacturer, in compliance with current
safety standards and the instructions in this manual.
• Identify the specific appliance model. The model number is
detailed on the packaging and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.

13 CONVERSION TO A DIFFERENT TYPE OF GAS

See Chapter " Instructions for installation ".

14 COMMISSIONING

Following installation, conversion to a different type of gas or
any maintenance operations, check appliance operation.In the
event of any malfunction, consult the next Paragraph "Trou-
bleshooting".
14.1 GAS APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the gas supply pressure ( see next Paragraph ).
• the correct ignition of the burners and the effectiveness of the
fumes removal system.
14.1.1
CHECKING THE GAS SUPPLY PRESSURE
• To measure the gas supply pressure use a manometer with a
minimum definition of 0.1 mbar.
• Remove the control panel.
• Remove the screw from the pressure test point PP and con-
nect the manometer to the test point.
• Make the measurement with the appliance in operation.
IMPORTANT! If the gas supply pressure is not within the limits
( Min. - Max ) indicated in Table T2 , cease operation of the
appliance and contact the gas utility company.
• Disconnect the manometer and retighten the retaining screw
on the pressure connection.

15 TROUBLESHOOTING

15.1

WOK

The pilot burner does not light
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
Pilot burner goes out during use
Possible causes:
• Insufficient gas supply pressure.
• Defective gas tap or valve.
• Defective thermocouple or insufficient heating.
• Thermocouple incorrectly connected to gas tap or valve.
• Knob of gas tap or valve not pressed sufficiently.
The main burner does not light ( even though pilot is lit )
Possible causes:
6
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Defective burner ( gas outlet holes clogged ).

16 REPLACING COMPONENTS

REMINDERS FOR REPLACING COMPONENTS.

• After replacing a gas system component, check for gas leaks
at connection points.
• After replacing an electrical system component, check it is
correctly wired.
16.1
WOK
Replacing the gas tap.
• Remove the control panel.
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
Replacing the pilot burner and thermocouple.
• Remove the control panel.
• Remove the panstand grids and burners
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.

17 CLEANING THE INTERIOR

• Check the condition of the inside of the appliance.
• Remove any built-up dirt.
• Check and clean the fumes exhaust system.

18 MAIN COMPONENTS

18.1
WOK
• Gas tap
• Main burner
• Pilot burner
• Thermocouple
Tabla de contenido
loading

Tabla de contenido