Package contents
The package contains:
1 Table top mitre saw
1 Saw blade
1 Parallel rip fence
1 Upper blade guard
1 Push stick
1 Dust collection port (fig. V)
1 Torx® key T30
1 Torx® key T40
1 Instruction manual
1 Exploded drawing
• Check for damage to the tool, parts or accessories which may have
occurred during transport.
• Take the time to thoroughly read and understand this manual prior to
operation.
Description (fi g. A1 - A6)
Your D27111/D27112 table top mitre saw has been developed for
professional applications. This high precision machine can be easily and
quickly set to crosscut, bevel, mitre, or compound mitre.
Fig. A1
1 On/off switch
2 Operating handle
3 Head lock up release lever
4 Additional saw bench table locking knob
5 Moveable front lower blade guard
6 Fence right-hand side
7 Fixed table
8 Kerf plate
9 Mitre latch
10 Mitre lever
11 Rotating table/mitre arm
12 Mitre scale
13 Fence left-hand side
14 Bevel scale
15 Bevel clamp handle
16 Saw bench table locking knob
17 Head lock down pin
18 Rail lock knob
Fig. A2
19 Saw bench table
20 Riving knife
21 Upper blade guard
22 Parallel rip fence
23 Push stick location
24 Moveable rear lower blade guard
25 Attachment mounting holes
26 Hand indentation
Optional accessories
Fig. A3
27 Material clamp
Fig. A4
28 Legstand
Electrical safety
The electric motor has been designed for one voltage only.
Always check that the power supply corresponds to the voltage on the
rating plate.
15 V units have to be operated via a failsafe isolating
transformer with an earth screen between the primary and
secondary winding.
D27111
This machine is of class 1 construction; therefore earthed (grounded)
connection is required.
D27112
This machine is double insulated in accordance with
EN61029; Therefore no earth wire is required.
Mains plug replacement
(U.K. & Ireland only)
• Should your mains plug need replacing and you are competent to do
this, proceed as instructed below. If you are in doubt, contact an
authorized D
WALT repair agent or a qualifi ed electrician.
E
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug with bared copper
conductors is dangerous if engaged in a live socket outlet.
• Only fi t 13 Amperes BS1363A approved plugs fi tted with the correctly
rated fuse (1).
• The cable wire colours, or a letter, will be marked at the connection
points of most good quality plugs. Attach the wires to their respective
points in the plug (see below). Brown is for Live (L) (2), blue is for
Neutral (N) (4) and green/yellow is for Earth (E).
• Before replacing the top cover of the mains plug ensure that the
cable restraint (3) is holding the outer sheath of the cable fi rmly and
that the leads are correctly fi xed at the terminal screws.
4
3
Never use a light socket.
Never connect the live (L) or neutral (N) wires to the earth
pin marked E or
For 115 V units with a power rating exceeding 1500 W, we recommend
to fi t a plug to BS4343 standard.
Using an extension cable
If an extension cable is required, use an approved extension cable
suitable for the power input of this machine (see technical data).
The minimum conductor size is 2.5 mm
When using a cable reel, always unwind the cable completely.
Also refer to the table below.
2
Conductor size (mm
)
Cable rating (Amperes)
0.75
6
1.00
10
1.50
15
2.50
20
4.00
25
E N G L I S H
1
2
.
2
.
31