• Charging a battery with the positive pole grounded: Connect the black cable to the
negative pole of the battery and the red cable to the chassis of the vehicle. Be sure
that the black cable is not in the proximity of the battery, carburetor, fuels places or
fine metallic parts.
• Before the disconnection of the battery cable turn the charger off or disconnect it
from the AC Supply.
Connecting the charger in a battery that is NOT MOUNTED in the vehicle:
• Be careful with the polarity of batteries. The POSITIVE (POS, P , +) terminal is nor
mally greater than the negative terminal (NEG, N, -).
• Connect he red cable to the positive pole and the black cable to the negative pole
of the battery. Case wrong connection is made, a protective circuit in the charger
avoid damaging the battery or the charger.
• When switching the battery off, proceed always in the opposite sequence of
connection.
Panel description
A Button to switch ON/OFF the charger
1 Indicator of full battery and float current mode.
2 Indicator of charging battery
3 Indicator of Error: The battery is not corrected connected and/or over-discharged
C Button Reactivation
4 Indicator of active reactivation mode.
B Button to configure the charging mode or active SERVICE operation
6 Charging Mode 12V 2A indication
7 Charging Mode 12V 8A indication
8 Charging Mode 12V 16A indication (light), SERVICE – Operation (blinking)
11