CLEANING DIAPHRAGM AND FILTER
1. Turn the screw on the control stop clockwise to turn off the water.
2. Disconnect the solenoid.
3. Remove the solenoid and take out the diaphragm.
4. Check the small holes and sealing.
NOTE: See this page below for disassembly.
NOTE: Do not stretch or alter the shape of the spring in the solenoid valve in any way. It
will void the warranty.
Flow regulator
Filter
Filter
CHECKING SOLENOID
1. Make sure that the batteries are properly placed and wires are connected.
2. With water supply turned off, place your hand in front of the sensor for 6 seconds
3. Remove and listen for a "click" sound after 3 seconds. This indicates the solenoid
plunger has been activated.
BATTERY REPLACEMENT
A special lithium back-up battery is used. Replace
only with the included TOTO back up battery. If a red
light in the sensor window blinks with the cycle of
4 seconds, it is time to replace the battery.
1. Remove the old battery.
2. Set the new battery at the proper position.
ADJUSTMENT OF THE FLOW RATE
1. Adjust the flow rate by the turning screw on the control stop.
2. Turn the screw to the right to decrease the flow rate and turn to the left to increase.
Solenoid
Spring
Plunger
O-ring
Cap
Diaphragm
Filter
TEU2UA(R)(X) and TEU3UA(R)(X)
18
Sensor unit
Filter
Battery