INSTALLATION PROCEDURE — SMALL COVER
6. Pass the flush pipe and the vacuum
breaker through the guide hole (Step 3)
and mount them on the bowl.
7. If required, cut the vacuum breaker
tube to the proper length.
8. Make sure that the o-ring fits in the
groove at the end of the Flush Valve
tailpiece.
9. Exercise care to prevent damage to
the o-ring when inserting the tailpiece
into the control stop. For additional
lubrication, wet the o-ring with water.
10. Connect the Flush Valve with the control
stop and vacuum breaker tube.
11. Tighten the coupling nut with a wrench to
prevent a water leak.
TET3LA(X)32, TET3GA32, TET3UA(X)32
TEU3LA(X)12, TEU3UA(X)12
7" (178mm) min space
in wall with a min
12" x 12" access panel
or walk-in chase
Wall surface
6~6-1/2"
(152~165mm)
1-1/2" (38mm)
or 3/4" (19mm)
Top spud
5"
(127mm)
2-1/4"~2-3/4"
(57~70mm)
3-3/4"~4-7/8"
Bowl or Urinal
(95~124mm)
TET3LA(X)33, TET3UA(X)33
TET3GA33
7" (178mm) min space
in wall with a min
12" x 12" access panel
or walk-in chase
Wall surface
Back spud
1-1/2"
Floor mount
(38mm)
Bowl
3-3/4"~4-7/8"
(95~124mm)
12
TET3LA(X)31, TET3UA(X)31
TET3GA31
7" (178mm) min space
in wall with a min
12" x 12" access panel
or walk-in chase
Wall surface
Back spud
Wall mount
3"
(76mm)
3-3/4"~4-7/8"
Bowl
(95~124mm)
TEU3LA(X)11, TEU3LA(X)21
TEU3UA(X)11
7" (178mm) min space
in wall with a min
12" x 12" access panel
or walk-in chase
Wall surface
1-1/4" (32mm)
or 3/4" (19mm)
Urinal
3-3/4"~4-7/8"
(95~124mm)
O-ring
Snap ring
1-1/2"
(38mm)