IMPORTANT! When all field wired connections are completed in
the junction box located on top of the ceiling section, be sure to
THOROUGHLY SEAL the wiring conduit on both the exterior (where
the conduit enters the interior from the roof), the interior conduit
penetration through the ceiling and the conduit termination within
the junction box. The silicone sealant provided is well suited for this
purpose. Failure to adequately seal the conduit will allow moisture
to form within the junction box and electrical fixture(s) and potentially
cause a short circuit.
To prevent possible damage to the door opening heater and/or to the
protective globe over the interior light, DO NOT energize the door/
door section until the interior temperature has been reduced to the
normal operating range by refrigeration. A caution label is affixed to
the door section near the vapor proof light to serve as a reminder.
18
-E
C
LECTRICAL
ONNECTIONS
WIRING DIAGRAM: A wiring
diagram showing the electrical
components contained in the
door/door
section
circuitry
involved as shown.
Always
refer to the wiring diagram if it
becomes necessary to replace
any of the components.