A standard door/door section consists basically of a single wall
panel that contains an entrance door and several accessories. The
electrical components contained in this panel were prewired at the
factory. They include the anti-condensate door opening heater, the
pilot light, and switch and a vapor proof interior light.
The door was factory installed on the door panel framing fixture,
checked for squareness and for proper operation under controlled
conditions.
CAUTION! While installing the door/door section, extreme care must
be taken to avoid twisting the panel or handling the assembly in such
a manner that it is not square when it is installed. The self-closing
feature, door closure operation and a perfect gasket seal all depend
a great deal upon a SQUARE and PLUMB door/door section.
After all the wall and door panels have been erected and locked
securely together and all the ceiling panels have been positioned
above the wall panels, the ceiling panels have been locked securely
to each other, re-check the position of the ceiling panels with respect
to the wall panels.
Now lock all ceiling panels securely to the wall panels.
Recheck the position of the wall panels with respect to the floor
panels and lock them securely together.
NOTE: When a 1" vinyl floor sealer (screed) is used, no attachment
to the wall panels is required.
Completed Kold Locker
Walk-in
Completed Kold Locker
Walk-in with floor
floorless- shown with vinyl floor
sealer