If the appliance's power cable is in any way damaged it should be replaced by
an authorized installer, as this requires special tools. All internal wires,
conductors, earth connections and home automation are of section 1 mm.

6. HOME AUTOMATION CONNECTION

In addition to live and neutral wires, the heater also features a black wire, which
is the home automation network wire. EMIDRY appliances are factory-ready for
receiving Gifam-compliant home automation signals. To enable home
automation functionality all the black wires in all appliances configured in the
heating installation must be connected to each other, and connected in turn
(from any point) to the home automation controller. The order of connection is
irrelevant; all wires may be connected to a single point, linked by a serial
connection, or a combination of the latter two solutions may be used. The only
essential requirement is that all black wires are connected to each other and to
the controller. These wires carry a different voltage (max. 230 V~) but a very low
current. We recommend using insulated black wire of the same section as the
other wires in the installation.
Wires should be connected using single-wire connection blocks, of size
suitable
to the wire section. If one, several or all appliances are to operate
independently,
the black wires in these appliances should remain unconnected, with the tips
suitably insulated.