Switching On The Pump; Remedy Of Faults - Oase AquaMax Eco Titanium 31000 Instrucciones De Uso

Ocultar thumbs Ver también para AquaMax Eco Titanium 31000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
- EN -
Commissioning/start-up
N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
• Do not connect the unit to a dimmable power supply.
The formation of a small amount of rust on the pump is completely normal in a damp environment.
When started up, the pump automatically performs a pre-programmed self-test (Environmental Function Control
(EFC)). The pump detects if it is running dry / blocked or submerged. The pump switches off automatically after ap-
prox. 90 seconds if it runs dry/is blocked. In the event of a malfunction, disconnect the power supply and "flood the
pump" or remove the obstacle. Afterwards, the unit can be restarted.

Switching on the pump

• Connect the unit to the power supply.
Switching off the pump
• Disconnect the pump from the power supply.

Remedy of faults

Malfunction
Pump does not start
Pump does not transport fluid
Insufficient delivered quantity
Pump switches off after a short running period.
26
Cause
No mains voltage
Excessively soiled water
The impeller unit is blocked
Impeller unit is running sluggishly
Excessive loss in the pipes due to friction
Excessively soiled water
Water temperature too high
Ambient temperature too high
The impeller unit is blocked
Pump has run dry.
Remedy
− Check the mains voltage.
− Check supply lines.
− Switch on the pump.
− Clean the pump. The pump automatically
switches on again once the motor has
cooled down.
− Disconnect the power supply and remove
obstacle. Then switch the pump on again.
− Clean
− Select a larger pipe diameter.
− Reduce pipe length to the necessary min-
imum.
− Avoid unnecessary bends and connection
elements.
− Clean the pump. The pump automatically
switches on again once the motor has
cooled down.
− Note maximum water temperature of
+35°C. The pump automatically switches
on again once the motor has cooled down.
− Adhere to the maximum permissible ambi-
ent temperature. The pump automatically
switches on again once the motor has
cooled down.
− Disconnect the power supply and remove
obstacle. Then switch the pump on again.
− Flood the pump. Fully submerge the pump
for operation in the pond.