Part no
2050479303
Issue no
02
Series no
-
Date
12/2006
Page
8 / 218
GROUPS
The group setting is the number of fasteners that need to be completed before the FAS3000 issues a GROUP-ACCEPT
output. If the sequencing feature is turned on, the group setting represents the number of fasteners that must be
completed before switching to the next parameter set in the sequence. A GROUP ACCEPT will be issued after the final
parameter set in the sequence is completed.
FAS 3000 FLOW CHART
This number represents the number of fasteners in a GROUP.
One of the digits will be flashing. Use the up and down arrow
keys to increment or deincrement the flashing digit. Use the left
and right arrow keys to select the next digit for editing. The
maximum GROUP is 255.
Use these buttons on the keypad to
increment or deincrement the flashing digit.
Use these buttons to edit the next digit.
Press this key to save the change and exit
the menu option.
Press this key to exit the menu option
without making the change.