Reset Operation - CP Desoutter FAS 3000 Manual Del Usuario

Ocultar thumbs Ver también para Desoutter FAS 3000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
FAS 3000 FLOW CHART

RESET OPERATION

In the event of a NOK, an error code will be displayed and the beeper will sound. The FAS3000 will need to be reset in
order to continue operating. The RESET button will clear the error status and allow the operator to finish the group of
fasteners. If the solenoid driver is enabled, the solenoid output will no longer source +24VDC.
GROUP RESET OPERATION
In the event of a NOK, an error code will be displayed and the beeper will sound. The FAS3000 will need to be reset in
order to continue operating. The GROUP RESET will clear the error code and reset the count to zero. If sequencing is
enabled, the FAS3000 will also go back to the beginning of the sequence. If the solenoid driver is enabled, the solenoid
output will no longer source +24VDC.
Part no
Issue no
Series no
Date
Page
In the event of a NOK, a cycle reset can be
performed by pressing this button.
In the event of a NOK, a GROUP RESET can be
performed by unlocking the unit with the key or
password and pressing this button.
2050479303
02
-
12/2006
19 / 218